About Company
The “Pharmec” company was found in 1990. The company specializes in the development, production and technical support of the Gas safety equipment: leak detectors, explosive-gas indicators and gas-analyzers (both portable and stationary).
 
Main
вторник, 13 мая 2008
 
 
Gas Analyzer FP 11.2K Print E-mail
вторник, 14 ноября 2006
Image Gas analyzer FP 11.2K – measuring explosion-proof device with digital indication, light and voice signalization and built-in micropump. Gas analyzer FP 11.2K designed for measuring volume fraction of one of inflamable gases(methane, propane or oxygen) in air and light and sound signalization in case of volume fraction bounds violation. The device is used for control of gase cocentration in air in industial buildings, wells, cellars, holec etc. where dangerous and highly explosive gases categories IIА, IIВ, IIС, groups Т1...Т5 according GOST 12.1.011 can be found. Gas analyzer calibrating is available for methane and propane.

 

 

Specifications

Analyze method: The basical principe of analyze is registration changes in resistance of catalytic thermal sensor affected by gas.

Size, mm: 35 х 60 х 185

Wieght,g: 430

Voltage, V: 4,1 to 5,8

Power, W: 3,0

Reporting ranges:
- methane volume fraction,% 0-5,0
- propane volume fraction,% 0-2,0

Measuring ranges:
- methane volume fraction,% 0-2,50
- propane volume fraction,% 0-1,00

Signalization limits:
- methane volume fraction,% 1,00
- propane volume fraction,% 0,40
Absolute measurement accuracy:
- methane volume fraction,% +0,25
- propane volume fraction,% +0,10

Signalization absolute measurement accuracy:
- methane volume fraction,% +0,05
- propane volume fraction,% +0,02

Additional absolute measurement accuracy depending on 10oС temperature changes:
- methane volume fraction,% +0,05
- propane volume fraction,% +0,02

Time for values to become 90%, sec : ≤ 10

No-load voltage of sparksafe
electrical chains, V: ≤ 5,8

Short-circuit current, A: ≤ 0,6

Non-stop working time
using accumulator, hours: ≥ 8

Nominal micropump productivity, h/min: ≥ 0,3

Expluatation conditions: air temperature from -20 to +50 oС, atmosphere pressure from 84,0 to 106,7 kPA and relative air humidity to 98% at 25 oС

Power source: NI-MN accumulators 4/5 A 1800 MAH

Calibrating(selfcalibrating): methane and propane using password

Highlight/Accumulator discharge indicator: available

Average life period: 10 years or more

Average worked time ≥ 30000
before refusal, hours:

Interverification interval: 1 time a year

Gas analyzrer adjustment and diagnostics
using infrared IR TECAd is available: delivered separately

Note: signalization limits can be changed on customer’s request

Last Updated ( вторник, 14 ноября 2006 )
 